Ex d Led Floodlights
Ex d 80~120W LED Lighting
Ex d ,LED,80W*1/100W*1/120W*1,AC90~305/380/460V,Ex d IIB+ H2 T6 Gb X、Ex tb IIIC T85℃ Db X
Use with explosion-proof cable glands or explosion-proof hoses
Ex d 30W LED Lighting-S3 DOB
Explosion-proof mark | |
Explosion Proof Mark | EX |
Gas Explosion-proof Type | d |
Dust Explosion-proof Type | tD(ta,tb,tc) tb |
Gas Hazardous Location Group | IIB |
Dust Hazardous Location Group | IIIC |
Special Gas Marking | H2 |
ambient temperature Classes for Gas | T6 |
ambient temperature Classes for Dust | T85℃ |
EPL: Equipment Protection Level-Gas | Gb |
EPL: Equipment Protection Level-Dust | Db |
IP Enclosure Ratings | IP66 |
Product specifications | |
Body Size | Ø(mm)diameter 181 High(H) 223 |
Electric Current | AC220V |
Voltage | 60 |
Operating Temperature | -20~+40/60 |
Rated Wattage | 30 |
Color Temperature | 5700 |
Light Bulb/Tube Quantity | 1 |
Light Bulb/Tube Type | LED |
Fixed Way | Wall-mounted Ceiling Mounting |
Bracket Selection | Wall-mounted Angle adjustment bracket |
Product source | Made in Taiwan |
Description:
Lamp chip brand adoption
CREE
NICHIA
OSRAM
PHILIPS LUMILEDS
Ex d 60W LED Lighting-S3 DOB
Explosion-proof mark | |
Explosion Proof Mark | EX |
Gas Explosion-proof Type | d |
Dust Explosion-proof Type | tD(ta,tb,tc) tb |
Gas Hazardous Location Group | IIB |
Dust Hazardous Location Group | IIIC |
Special Gas Marking | H2 |
ambient temperature Classes for Gas | T5 /T4 |
ambient temperature Classes for Dust | T100/T120°C |
EPL: Equipment Protection Level-Gas | Gb |
EPL: Equipment Protection Level-Dust | Db |
IP Enclosure Ratings | IP66 |
Product specifications | |
Body Size | Ø(mm)diameter 181 High(H) 223 |
Electric Current | AC220/460V |
Voltage | 60 |
Operating Temperature | -20~+40/+60 |
Rated Wattage | 60 |
Color Temperature | 5700 |
Light Bulb/Tube Quantity | 1 |
Light Bulb/Tube Type | LED |
Fixed Way | Wall-mounted Ceiling Mounting |
Bracket Selection | Wall-mounted Angle adjustment bracket |
Product source | Made in Taiwan |
Description:
Lamp chip brand adoption
CREE
NICHIA
OSRAM
PHILIPS LUMILEDS
Ex d 100W LED Lighting-M3 DOB
Explosion-proof mark | |
Explosion Proof Mark | EX |
Gas Explosion-proof Type | d |
Dust Explosion-proof Type | tD(ta,tb,tc) tb |
Gas Hazardous Location Group | IIC |
Dust Hazardous Location Group | IIIC |
ambient temperature Classes for Gas | T5 /T4 |
ambient temperature Classes for Dust | T100/120°C |
EPL: Equipment Protection Level-Gas | Gb |
EPL: Equipment Protection Level-Dust | Db |
IP Enclosure Ratings | IP66 |
Product specifications | |
Body Size | Ø(mm)diameter 241 High(H) 230 |
Electric Current | AC220V |
Voltage | 60 |
Operating Temperature | -20~+40/+60 |
Rated Wattage | 100 |
Color Temperature | 5700 |
Light Bulb/Tube Quantity | 1 |
Light Bulb/Tube Type | LED |
Fixed Way | Wall-mounted Ceiling Mounting |
Bracket Selection | Wall-mounted Angle adjustment bracket |
Product source | Made in Taiwan |
Description:
Lamp chip brand adoption
CREE
NICHIA
OSRAM
PHILIPS LUMILEDS
Ex d 120W LED Lighting-M3 DOB
Explosion-proof mark | |
Explosion Proof Mark | EX |
Gas Explosion-proof Type | d |
Dust Explosion-proof Type | tD(ta,tb,tc) tb |
Gas Hazardous Location Group | IIC |
Dust Hazardous Location Group | IIIC |
ambient temperature Classes for Gas | T4 |
ambient temperature Classes for Dust | T110/T130°C |
EPL: Equipment Protection Level-Gas | Gb |
EPL: Equipment Protection Level-Dust | Db |
IP Enclosure Ratings | IP66 |
Product specifications | |
Body Size | Ø(mm)diameter 241 High(H) 230 |
Electric Current | AC220V |
Voltage | 60 |
Operating Temperature | -20~+40/+60 |
Rated Wattage | 120 |
Color Temperature | 5700 |
Light Bulb/Tube Quantity | 1 |
Light Bulb/Tube Type | LED |
Fixed Way | Wall-mounted Ceiling Mounting |
Bracket Selection | Wall-mounted Angle adjustment bracket |
Product source | Made in Taiwan |
Description:
Lamp chip brand adoption
CREE
NICHIA
OSRAM
PHILIPS LUMILEDS
Ex d 150W LED Lighting-M3 DOB
Explosion-proof mark | |
Explosion Proof Mark | EX |
Gas Explosion-proof Type | d |
Dust Explosion-proof Type | tD(ta,tb,tc) tb |
Gas Hazardous Location Group | IIC |
Dust Hazardous Location Group | IIIC |
ambient temperature Classes for Gas | T4 |
ambient temperature Classes for Dust | T110/T130°C |
EPL: Equipment Protection Level-Gas | Gb |
EPL: Equipment Protection Level-Dust | Db |
IP Enclosure Ratings | IP66 |
Product specifications | |
Body Size | Ø(mm)diameter 241 High(H) 230 |
Electric Current | AC220V |
Voltage | 60 |
Operating Temperature | -20~+40/+60 |
Rated Wattage | 150 |
Color Temperature | 5700 |
Light Bulb/Tube Quantity | 1 |
Light Bulb/Tube Type | LED |
Fixed Way | Wall-mounted Ceiling Mounting |
Bracket Selection | Wall-mounted Angle adjustment bracket |
Product source | Made in Taiwan |
Description:
Lamp chip brand adoption
CREE
NICHIA
OSRAM
PHILIPS LUMILEDS
Ex d 100W LED Street Lighting-M3
Explosion-proof mark | |
Explosion Proof Mark | EX |
Gas Explosion-proof Type | d |
Dust Explosion-proof Type | tD(ta,tb,tc) tb |
Gas Hazardous Location Group | IIC |
Dust Hazardous Location Group | IIIC |
ambient temperature Classes for Gas | T6 /T5/T4 |
ambient temperature Classes for Dust | T85/T100/T105/T120℃ |
EPL: Equipment Protection Level-Gas | Gb |
EPL: Equipment Protection Level-Dust | Db |
IP Enclosure Ratings | IP66 |
Product specifications | |
Electric Current | AC100~240/277/380/460V |
Voltage | 60 |
Operating Temperature | -20~+40/+60 |
Rated Wattage | 100 |
Light Bulb/Tube Type | LED |
Fixed Way | Junction Box |
Bracket Selection | Straight / bent rod |
Dimensions(mm) | L(Icon A) 1344 W(Icon B) 330 H(Icon C) 5057 |
Product source | Made in Taiwan |
Description:
Lamp chip brand adoption
CREE
NICHIA
OSRAM
PHILIPS LUMILEDS
Ex d 120W LED Street Lighting-m3
Explosion-proof mark | |
Explosion Proof Mark | EX |
Gas Explosion-proof Type | d |
Dust Explosion-proof Type | tD(ta,tb,tc) tb |
Gas Hazardous Location Group | IIC |
Dust Hazardous Location Group | IIIC |
ambient temperature Classes for Gas | T5 /T4 |
ambient temperature Classes for Dust | T90/T110/T130℃ |
EPL: Equipment Protection Level-Gas | Gb |
EPL: Equipment Protection Level-Dust | Db |
IP Enclosure Ratings | IP66 |
Product specifications | |
Electric Current | AC100~240/277/380/460V |
Voltage | 60 |
Operating Temperature | 20+40/+60 |
Rated Wattage | 120 |
Light Bulb/Tube Type | LED |
Fixed Way | Junction Box |
Bracket Selection | Straight / bent rod |
Dimensions(mm) | L(Icon A) 1344 W(Icon B) 330 H(Icon C) 5057 |
Product source | Made in Taiwan |
Description:
Lamp chip brand adoption
CREE
NICHIA
OSRAM
PHILIPS LUMILEDS
Ex d 100~120W LED Street Lighting
Explosion-proof mark | |
Explosion Proof Mark | EX |
Gas Explosion-proof Type | d |
Dust Explosion-proof Type | tD(ta,tb,tc) tb |
Gas Hazardous Location Group | IIB |
Dust Hazardous Location Group | IIIC |
Special Gas Marking | H2 |
ambient temperature Classes for Gas | T6 |
ambient temperature Classes for Dust | T85℃ |
EPL: Equipment Protection Level-Gas | Gb |
EPL: Equipment Protection Level-Dust | Db |
Special Certification | X |
IP Enclosure Ratings | IP66 |
Product specifications | |
Electric Current | AC90~305V/380V/460V |
Voltage | 60 |
Operating Temperature | -20~+40 |
Rated Wattage | 100/120W |
Light Bulb/Tube Type | LED |
Fixed Way | Junction Box |
Bracket Selection | Straight / bent rod |
Dimensions(mm) | L(Icon A) 1344 W(Icon B) 330 H(Icon C) 5057 |
Product source | Made in Taiwan |
Description:
Light bulbs selection has (SDLW-0LD-1001ALL00),LED,100W*1/ (SDLW-0LD-1201ALL00 ),LED,120W*1, please make inquiries based on the wattage of the lamp, thank you.
Lamp chip brand adoption
CREE
NICHIA
OSRAM
PHILIPS LUMILEDS